OUR WORLDWIDE PROJECTS
OUR WORLDWIDE PROJECTS
WATER COOLED COB LED LIGHTS
Magnus light water-cooled COB lights are an ideal solution for the professional medicinal cannabis industry. The water-cooled fixtures can produce more light output than the air-cooled fixtures. Because of the little to no heat radiation from the fixtures the environmental conditions in the growing room are lower in costs to control. The heat in the water system can be re-used in many ways.. Also by the cooling the chips, the water-cooled fixtures have a lifespan of 100.000 hours.
MOST POWERFULL LED
DEEPER CANOPY PENETRATION
120 DEGREE PARABOLIC LENS
EMITS SUFFICIENT HEAT
INCREASED LIGHT INTENSITY
LITTLE TO NO HEAT RADIATION
MORE ABUNDENT GROWTH
EARLIER HARVEST
ENERGY EFFICIENT
100.000 LIFECYLE HOURS
SPECIAL LIGHT SPECTRUM
FAR-RED CONTROLL
MAGNUS 120 DEGREE PARABOLIC LENS

After extensive testing and subsequent adjustments, the precise balance between colors and wavelengths was developed resulting in the right spectrum. The balanced spectrum plus the chosen light intensity helps achieve more abundant and vigorous growth and superior quality of flower structure and yield. Our dedication, commitment and expertise have helped to develop the perfect LED. Magnus LED’s can be used during the entire plant cycle. We only use those colors that are necessary for cultivation. Because of this the highest efficiency attainable in the current market can be achieved.
MAGNUS SPECIAL LIGHT SPECTRUM
After extensive testing and subsequent adjustments, the precise balance between colors and wavelengths was developed resulting in the right spectrum. The balanced spectrum plus the chosen light intensity helps achieve more abundant and vigorous growth and superior quality of flower structure and yield. Our dedication, commitment and expertise have helped to develop the perfect LED. Magnus LED’s can be used during the entire plant cycle. We only use those colors that are necessary for cultivation. Because of this the highest efficiency attainable in the current market can be achieved.


PRO & WHITE VERSION
Magnus offers two different light spectrums; Pro & Standard "White". The first difference between the 2 versions is the visual light colour.
The pro version emits a pink colour while the standard "white" versions emits a white colour.
​
The Pro version has a better grow efficiency because all the light output is used by the plant
​
The Standard "white" version has more green and yellow colours than used by the plant. This makes a white visable light colour what some growers prefer but resulting in a little less efficient spectrum. Because the plant will not use as much green and yellow for photosynthesis
FARRED CONTROL
Our COB LED lamps are equipped with a separate farred dimmer or switch. This ensures that the user can control the vegetative phase of the plant.
​
In the vegetative phase this unique color can be dimmed separately. Once switched to the duration of hours needed for the flowering period, it can be switched on to simulate flower formation
​
This unique color provides the right temperature for nutrient uptake and because it is dimmable, the user can determine the evaporation of the plant. In the final phase this color can be dimmed again so that the flowers remain compact because they do not open due heat transpiration.
In order to achieve the best results. We advise to check our VPD information.



ML-365 (water-cooled)

Download the ML-365 WC statsheet
- Power consumption: 365 Watt
- Number of LEDs: 2x 100 LEDs
- PPFD: 310 μmol (distance 1000mm)
- Comparible with: >1000 Watt HPS
- Advised height: At least 60 cm above the canopy
- Footprint: 120x120 cm
- Farred control: Dimmable control
- Light spectrum RBFc or RBWFc
- Lifespan: +100.000 hours
- Weight: 6.7 kilogram
- Dimensions: W:303mm x L170mm x H160mm
- Warranty: 3 years
- Input voltage 100-240V AC Power Input
PRO
WHITE
€ 1099,-
€ 1199,-
PROFESSIONAL CHILLERS


The main features:
- specific disconnection alarm security protection
- Hermetic type water, water is available for a long time used
- Real-time temperature monitoring, accurate knowledge of heating devices working condition
- Professional air-cooled forced radiator with strong heat dissipating capacity and difficult to be blocked up
- Equipped with alarm output port to protect sensitive components quickly.
- High cost performance, Low failure rate
To protect the led diodes the cooler fan will suspend to work when the water temperature is lower than 10°c , and will restart to run when the water temperature rises higher than 20°c
Caution
- It is strictly forbidden to connect the chiller without water. DO NOT USE DISTILLED WATER!
- Cooler should be placed in a well ventilated, dry place away from heat sources.
- The cooling water should be drained and when the chiller has to be transported or when not in use for a long time.
- To protect equipment, the condenser cooling fan will suspend to work when the water temperature is lower
(10 degrees) and it will run again when the temperature rises to higher (20 degrees)